T-4101 1-In / 1-Out, without battery, 0.8 PF (1-15KVA)

The i-power T-4101 series is a true online double-conversion UPS that can provide your critical equipment with reliable and stable sine wave power. It features significant advantages, including an output power factor of 0.8 and up to 98% AC-AC efficiency for greater energy savings.
It is a versatile, high quality, and cost-competitive UPS developed to handle a wide voltage range and inconsistent power conditions. The T-4101 series provides a safe power supply guaranteed for mission-critical applications such as computer equipment, telecommunication devices, precision instrument, network termination equipment, and more.
Product Highlights:
- Wide Input Voltage Range; Single Phase 160Vac to 280Vac.
- High Efficiency 98% under ECO Mode.
- Battery low/over charged sensor to protect the charger.
- Advanced SCR rectifier and IGBT inverter technology.
- Surge current protection technology to manage sudden impact of 0% to 100% load immediately without transfer to bypass.
- Front to rear ventilation design to reduce the MTTR rate of the UPS.
| Model | OL1001T80600S | OL1002T80600S | OL1003T80800S | OL1006T81600S OL1006T80800S | OL1008T81600S | OL1010T81600S | OL1015T81600S |
| Capacity | 1KVA/0.8KW | 2KVA/1.6KW | 3KVA/2.4KW | 6KVA/4.8KW | 8KVA/6.4KW | 10KVA/8KW | 15KVA/12KW |
| Technical Specification | |||||||
| UPS Structure | Online Double Conversion | ||||||
| Topology | Low Frequency with Output Isolation Transformer | ||||||
| Overall Efficiency (AC-AC ) | > 85% | ||||||
| Noise(In 2 meters) | < 50dB | ||||||
| Working Temp | -10-40℃ | ||||||
| Storage Temp | -25 ~ 60℃(Without Batteries) | ||||||
| Humidity | < 95%Non-Condensing | ||||||
| Safety Standard | IEC62040 | ||||||
| Parallel Redundancy | Available | ||||||
| Protections | Overload, Short-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low | ||||||
| DC Start | Available | ||||||
| Generator Compatibility | Available | ||||||
| Display | LCD Display | ||||||
| IP Rating | IP20 | ||||||
| Cooling System | Intelligent Speed Control Cooling Fan | ||||||
| Elevation | <1000M,Without Derating | ||||||
| Rectifier Specification | |||||||
| Input Voltage | 200/220/230/240Vac Single Phase | ||||||
| Input Voltage Range | 160-280Vac | ||||||
| Input Frequency Range | 50Hz±5% | ||||||
| Soft-Start | > 20 Seconds | ||||||
| Output Specification | |||||||
| Output Voltage | 200/220/230/240Vac | ||||||
| Output PF | 0.8 | ||||||
| Output Voltage Regulation | 220Vac±1%( Static Load ),220Vac±2%(50~0% Sudden Change) | ||||||
| Output Freq | 50Hz±0.1%(BAT Mode) | ||||||
| Distortion | <1%(Linear Full Load),< 3%(Non-Linear Full Load) | ||||||
| Frequency Tracking Range | 46-54Hz | ||||||
| Output Waveform | Pure Sine Wave | ||||||
| Overload | > 125%: More than 1 Min; > 150%: More than 300ms | > 125%: More than 10 Mins; > 150%: More than 1 Min | |||||
| Noise Suppression | EMI/RFI Wave Filter | ||||||
| Crest Ratio | 3∶1 | ||||||
| Short-Circuit | Circuit Auto Protection,Output Voltage/Current 0 | ||||||
| Output Abnormal | INV. Output Auto-Locked Protection | ||||||
| Bypass Specification | |||||||
| Static Bypass Transfer Time | 0ms | ||||||
| Static Bypass Range | 220Vac(-15~+15%) | ||||||
| Frequency Range | ±1Hz, ±2Hz,±3Hz Adjustable | ||||||
| Bypass - INV Transfer Time | 2ms | ||||||
| Frequency Tracking Speed | 0.5-2hz/s | ||||||
| Manual Maintenance Bypass | None | Available | |||||
| Alarm Specification | |||||||
| Alarm | Utility Power Fault, BAT Voltage Low, Overload,UPS Fault | ||||||
| Mute | Auto | ||||||
| Battery Specification | |||||||
| Type | Sealed Lead Acid Maintenance Free | ||||||
| VDC | 72Vdc | 72Vdc | 96Vdc | 192Vdc / 96Vdc | 192Vdc | 192Vdc | 192Vdc |
| Charging Current | 5A - Standard 10A-Optional | 5A - Standard 10A-Optional | 5A - Standard 10A-Optional | 5A - Standard 10A-Optional | 5A - Standard 10A-Optional | 5A - Standard 10A-Optional | 5A - Standard 10A-Optional |
| BAT Low | Shutdown Protection | ||||||
| Communication Specification | |||||||
| Standard Communication Port | Rs232 | ||||||
| Optional | SNMP/RS485/ Dry Contact | ||||||
| Remote Software | Multi-functional Monitoring System, Online and BAT Mode Status, BAT Fault, Remote Control | ||||||
| Physical Parameters | |||||||
| Dimensions in mm(W×D×H) | 220×510×395 | 220×610×475 | 220×610×715 | ||||
| Net Weight (Kg) | 22.5 | 23.5 | 29 | 44 | 53 | 63 | 70 |
| Note:Specification are subject to change without further notice. | |||||||