T-4001 1-In / 1-Out, with built-in battery, (1-10KVA)

 

 

The i-power T-4001 series is a true online double-conversion UPS that can provide your critcal equipment with reliable and stable sine wave power. It features significant advantages, including an output power factor up to 0.9 and up to 90% AC-AC efficiency for greater energy savings.

It is a versatile, high quality, and cost-competitive UPS developed to handle a wide voltage range and inconsistent power conditions. The T-4001 series provides a safe power supply guaranteed for mission-critical applications such as computer equipment, telecommunication devices, precision instrument, network termination equipment, and more.

 

Product Highlights:

  • Wide Input Voltage Range allows the UPS to work in harsh environments and reduces battery discharging time.
  • GBT technology to achieve high overall efficiency up to 90%.
  • High input power factor (0.99) and low harmonic distortion (THDI 5%) saves upstream investment.
  • Can be connected with all kinds of generators to save customers costs.
  • True online double-conversion topology and zero transfer time to battery provides 24/7 full-time protection.
ModelOH1001T80307SOH1002T80607SOH1003T80807SOH1006T81607SOH1010T81607S
Capacity1KVA/0.8KW2KVA/1.6KW3KVA/2.4KW6KVA/4.8KW10KVA/8KW
ModelOH1001T90307SOH1002T90607SOH1003T90807SOH1006T91607SOH1010T92007S
Capacity1KVA/0.9KW2KVA/1.8KW3KVA/2.7KW6KVA/5.4KW10KVA/9KW
Technical Specifications
UPS StructureOnline Double Conversion - Tower Type
TopologyHigh Frequency, Transformer Less
Overall Efficiency (AC-AC )> 90%
Noise(In 2 meters)< 50dB
Working Temp0-40℃
Storage Temp-15 ~ 60℃(Without BATs)
Humidity< 95% Non Condensing
Safety StandardGB/T14715; EN62040-1
EMC StandardEN 50091-1/2, EN62040-2
ProtectionsOverload, Short-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low
Generator CompatibilityAvailable
DC StartAvailable
Manual Maintenance BypassNoneOptional
DisplayLCD/LED: UPS Status, INV Status, Bypass Status, BAT Status, BAT %, Load %, Fault Messages
AlarmAuto
MuteAuto
Rectifier Specification
Input Voltage Range100% Load:160~300Vac,50% Load:115~300Vac175 ~ 280Vac
Input Frequency Range45-65Hz(Auto Tracking)
Input PF0.99
THDI< 5%
Output Specification
Output Voltage220Vac
Output PF0.8/0.9
Output Voltage Regulation220Vac±1%(Static Load);220Vac±2%(50-0% Sudden Change);220Vac±3%(100-0% Sudden Change)
Output Freq. (BAT Mode)50Hz± 0.2%
Output WaveformPure Sine wave
Distortion< 1%(Linear Full Load),< 3%(100% Non-Linear Load)
Overload> 125%: More than 1 min
> 150%: 300 ms transfer to bypass
> 120%: More than 1 min
> 150%: 300ms transfer to bypass
Crest Ratio3∶1
Efficiency> 90%
Short-CircuitCircuit Auto Protection, Output Voltage/Current 0
Output AbnormalINV Output Auto-Locked Protection
Noise SuppressionEMI/RFI Wave filter
BAT LowShutdown Protection
Dynamic Response3% at full load,recovering in 20ms
Auto-RestartAvailable
Software ControlAvailable
Bypass Specification
Static Bypass Transfer Time0ms
Static Bypass Range80Vac± 5%~285Vac±5%
Bypass - INV Transfer Time2ms
Battery Specification
TypeSealed Lead Acid Maintenance Free
VDC - Ah24Vdc/36Vdc-7Ah48Vdc/72Vdc - 7Ah72Vdc/96Vdc-7Ah192Vdc-7Ah192Vdc/240Vdc-7Ah
Charging Current1A1A1A1A1A
Communication Specification
Standard Communication PortRs232
OptionalSNMP/RS485/ Dry Contact
Remote SoftwareMulti-functional Monitoring System, Online and BAT Mode Status, BAT Fault, Remote Control
Physical Parameters
Dimensions in mm (D×W×H)405×145×220345×196×345500×240×616
Net Weight Kg12.52529.55760
Note:Specification are subject to change without further notice.