T-6003 3-In / 3-Out, High frequency, without battery, 1 PF (50-600KVA)

The i-power T-6003 series is a true online double-conversion modular UPS that can provide your critical equipment with reliable and stable power. It features significant advantages, including hot-swappable modular structure and N+X redundancy. With its high efficiency, this series delivers remarkably low total cost of ownership and operating expense.
The i-power T-6003 is the ultimate modular UPS series for Data centres and other critical loads. The UPS is designed to protect any critical high-density computer and IT environment, while achieving maximum availability. The T-6003 series grows along with the demands of the business without over-sizing the UPS, optimizing both the initial investment and the total cost of ownership.
Product Highlights:
- 96% overall efficiency for low running costs.
- Modular design provides easy maintenance and scalability.
- Hot-swappable function ensures uninterrupted operations during maintenance.
- Each module has built-in bypass breaker and bypass inductance to keep better system reliability.
- The advanced technologies deployed within the UPS guarantees full rated power without any power downgrading even when operating at temperatures up to 40°C.
| Cabinet Model | MH3300U15000S | MH3400U15000S | MH3500U15000S | MH3600U15000S |
|---|---|---|---|---|
| Cabinet Capacity in (KVA) | 300KVA | 400KVA | 500KVA | 600KVA |
| Module | MH3050M10000S | |||
| Module Capacity | 50KVA / 50KW | |||
| Host Machine Specification | ||||
| UPS Structure | Online Double Conversion | |||
| Appearance | Standard Telecomm Cabinet with Modular Structure Design | |||
| Overall Efficiency | > 96% | |||
| Noise(In 2 Meters) | < 70dB | |||
| Working Temp. | 0-40℃ | |||
| Storage Temp. | Minus 25 ~ 55℃(Without Battery) | |||
| Humidity | <95% Non-Condensing | |||
| Safety Standard | IEC62040 | |||
| EMC Standard | CE,YD/T1095-2008,EN /IEC 62040-2,EN/IEC 62040-1-1 | |||
| Parallel Redundancy | Modular Parallel upto 12 Units, Available for Rack Parallel. | |||
| Protection | Overload, Short-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low | |||
| DC Start | Available | |||
| Generator Compatibility | Available | |||
| Display | LCD + LED | |||
| Mute | Auto | |||
| IP Rating | IP20 | |||
| Cooling System | Intelligent Speed Control Cooling Fan | |||
| Elevation | <1000M without derating, >1000M: Derating 1% every 100M | |||
| Rectifier Specification | ||||
| Input Voltage | 380/400/415Vac+N+W, 3 Phase | |||
| Input Voltage Range | 135-485Vac | |||
| Input Frequency Range | 40-70Hz | |||
| Soft-Start | > 60 Seconds | |||
| Input PF | 0.99 | |||
| THDI | ≤ 3%(100% Non-Linear Load) | |||
| Output Specification | ||||
| Output Voltage | Line Voltage: 380/400/415×(1±1%)AC or Phase Voltage: 220×(1±1%)AC | |||
| Output Power Factor | 1 | |||
| Output Voltage Regulation | 380Vac±1%(Static Load);380Vac±2%(50-0% Sudden Change);380Vac±3%(100-0% Sudden Change) | |||
| Output Frequency | Synchronization with Input at online mode. When differences are greater than ±10% (Selectable±1%,2%,4%,5%) Output freq. will be 50×(±0.2)Hz 50Hz±0.2% (BAT Mode) | |||
| Distortion | <1%(Linear Full Load); < 3%(Non-Linear Full Load) | |||
| 3 Phase Unbalanced | Allow 3 Phase 100% Unbalanced | |||
| Output Volt. Unbalanced Degree | ≤1°(Balanced Load),≤2°(50% Balanced Load) | |||
| Input/Output Phase Swift | ≤1°(Balanced Load),≤2°(50% Balanced Load) | |||
| Frequency Tracking Range | 47-63Hz | |||
| Output Waveform | Pure Sine Wave | |||
| Overload | 110%: More than 60 mins | |||
| > 125%: More than 10 min; | ||||
| > 150%: More than 60 Seconds then transfer to bypass | ||||
| Crest Ratio | 3∶1 | |||
| Efficiency | > 96% | |||
| Short-Circuit | Circuit Auto-Protection, Bypass Switch Tripping | |||
| Output Abnormal | INV. Output Auto-Locked Protection | |||
| Bypass Specification | ||||
| Static Bypass Transfer Time | 0ms | |||
| Static Bypass Input Range | Bypass Protection upper limit:+15% (adjustable +5%、+10%、+25%) Bypass Protection lower limit: - 4 5 % ( adjustable - 2 0 %、 - 3 0 % ) Bypass Frequency Protection Range:±10% | |||
| Frequency Range | ±1Hz | |||
| Bypass - INV Transfer Time | 2ms | |||
| Frequency Tracking Speed | 0.5-2hz/s | |||
| Manual Maintenance Bypass | Available | |||
| Battery Specification | ||||
| Type | Sealed Lead Acid Maintenance Free | |||
| VDC | ±180/192/204/216/228/240/252/264/276/288/300V DC | |||
| Charging Current / Module | 20A max | |||
| BAT Low | Shutdown Protection | |||
| Communication Specification | ||||
| Communication Port | RS232/SNMP/485/ Dry Contact(Optional Accessory) | |||
| Remote Software | Multi-functional Monitoring System, Online and BAT Mode Status, BAT Fault, Remote Control | |||
| Physical Parameters | ||||
| Module Size mm (W×D×H) | 440x620x130/3U | |||
| Cabinet Size mm (W×D×H) | 600×850x2000 | 600×850x2000 (Standard) 1200x850x2000 (Full-Size) | 1200x850x2000 (Full-Size) | |
| Module Net Weight (Kg) | 32 | |||
| Cabinet Net Weight (Kg) | 260 | 280 / 600 | 645 | 720 |