UPS Solutions
On-Line High Frequency Series
T-4001 1-In / 1-Out, with built-in battery, (1-10KVA)
T-4001 1-In / 1-Out, without battery, (1-10KVA)
T-4002 3-In / 1-Out, without battery, (10-20KVA)
T-4003 3-In / 3-Out, without battery, (10-120KVA)
T-4003 3-In / 3-Out, compatible with built-in battery, (10-40KVA)
T-4003 3-In / 3-Out, Eco Series, with battery, (10-20KVA)
T-4003 3-In / 3-Out, Eco Series, without battery, (10-40KVA)
On-Line Low Frequency Series
T-4101 1-In / 1-Out, built-in battery, (1-6KVA)
T-4101 1-In / 1-Out, without battery, (1-15KVA)
T-4102 3-In / 1-Out, without battery (6-30KVA)
T-4103 3-In / 3-Out, without battery, (10-120KVA)
T-4103 3-In / 3-Out, without battery, (160-600KVA)
Rack-Mountable Series
T-4111 1-In / 1-Out, Low frequency, without battery, (1-10KVA)
T-4011 1-In / 1-Out, High frequency, built-in battery, (1-10KVA)
T-4011 1-In / 1-Out, High frequency, without battery, (1-10KVA)
T-4012 3-In / 1-Out, High frequency, without battery, (10-20KVA)
Modular Series
T-6003 3-In / 3-Out, High frequency, without battery, (30-300KVA)
T-6003 3-In / 3-Out, High frequency, without battery, (50-600KVA), 1 PF (50-600KVA)
Custom Design Online UPS
1 Phase In - 1 Phase Out
T-4101A (3-10kVA)
T-8001 (1- 3kVA)
T-8002(1- 10kVA)
Line Interactive UPS
T-3101 1-In/1-Out, Pure sine wave, built-in battery, (1-3KVA)
T-3101 1-In/1-Out, Pure Sine wave, without battery, (1-10KVA)
T-3001 1-In/1-Out, Modified Sine wave, built-in battery, (400-3000VA)
Online Inverter Series
Power Inverter Series
Automatic Voltage Regulators/Line Conditioners
AVR-1000 (Servo Control)
Single Phase (10-100kVA)
Three Phase (10-3000kVA)
AVR-1001 (Static Control)
Single Phase (1-50kVA)
Three Phase (10-2000kVA)
AVR-1002 (Relay Control)
Single Phase (1-20kVA)
Optional UPS Components
SNMP Adaptor/Card
Static Transfer Switches
Single Phase 3-32A
Three Phase 100-400A
i-power Remote Management System (RMS)
Battery Solutions
AGM Valve Regulated Sealed Lead Acid 12Volt
E-GFM Series Range: 5Ah – 200Ah
Gel Valve Regulated Sealed Lead Acid 12Volt
E-GH Series Range: 26Ah – 200Ah
Pure Gel (Deep Cycle) Valve Regulated Sealed Lead Acid 12Volt
E-GD Series Range: 26Ah – 200Ah
AGM (Deep Cycle) Valve Regulated Sealed Lead Acid 12Volt
E-AD Series Range: 26Ah – 200Ah
Battery Cabinets and Racks
7Ah-200Ah

Single Phase (1-50kVA)

The i-power single phase AVR-1001 static voltage regulator features continuous seamless correction of voltage, surges, spikes, sags & brown-outs. The AVR-1001 offers wide range voltage stabiliser, used to cope with input voltage down to 88V, and output voltage regulated to rated 220V without de-rating the input power. The AVR-1001 is designed to be compact and light in weight, assisting in tight regulation of power quality, without switching the active power path. This series is ideal for real-time voltage control, along with the benefits of excellent inbuilt surge voltage protection and electrical noise control circuits, thereby making it cost effective and highly reliable.

Product Highlights

  • Extremely wide voltage regulation range 88-264Vac (L-N), option for customisation is available.
  • 1kVA-50kVA single phase, rated voltage can be customised.
  • Individual regulation of each phase for unbalance load.
  • Unique small dimension.
  • Reliable and quiet servo motors.
  • Wheels mounted for easy installation.
  • Overvoltage and under voltage cut off delay.
  • Sine wave output (regardless of input waveform).
  • High Mean-Time-Between-Failure (MTBF).
  • Bypass switch available for easy maintenance.
  • Auto power-on function on request.
  • Voltage correction rate 1000V/sec.

Application

  • Telecom
  • Medical
  • Industrial
  • Commercial
  • Household appliances
Capacity1KVA-50KVA
Technical Specifications
System VoltageNominal system voltage 380/220 V, or other rated voltage
Input Voltage88-290V, Can be customizable as per requirement
Supply Frequency50/60Hz
Voltage Regulation ModeIndependent phase regulation
Insulation ClassH Class
Regulation Accuracy±2.5% (adjustable, 1-5 %)
Cooling TypeNatural Air(AN)/Forced Air(AF)
Duty TypeContinuous
Undervoltage ProtectCut off 242 V (adjustable), delay 4 -7 s
Overvoltage ProtectCut off 176 V (adjustable), delay 4 -7 s
Operational Temperature-20 C to +45 C
Efficiency>98%
Protection ClassIngress protection IP20 (outdoor version customization)
Electrical SafetyCE equivalent
Relative Humidity<90%
Physical Characteristics
Dimensions (WxDxH)230*480*740