T-3001 1-In/1-Out, Modified Sine wave, built-in battery, 0.6PF (400-3000VA)
The i-power T-3001 series is designed with Full-Digitised control with comprehensive monitoring and protections. The automatic voltage regulator (AVR) provides protection from surges, overvoltages and undervoltages, without battery intervention.
The integrated Automatic Voltage Regulation (AVR) ensures all electronics are receiving stable power while providing higher availability. It is a reliable and cost-effective power protection for PCs, monitor, POS, and other sensitive electronics used in offices and businesses. The T-3001 series’ Cold start function, auto-shutdown software and other superior features make these units perfect for your data protection.
Product Highlights:
- Wide input voltage range allows the UPS to work in harsh environments and reduces battery discharging time.
- The integrated AVR stabilizes the output voltage for better power quality.
- Ability to switch on the UPS in the absence of mains power.
- Auto restart (when mains power is restored, after discharge of the batteries).
- USB/RS232 & RJ-11/RJ45 serial port interface (Optional).
Model | LH1X40T60104S | LH1X60T60107S | LH1X80T60109S | LH1001T60207S | LH11X2T60207S | LH11X5T60209S | LH1002T60209S | LH1003T60409S |
Capacity | 400VA/240W | 600VA/360W | 800VA/480W | 1000VA/600W | 1200VA/720W | 1500VA/900W | 2000VA/1200W | 3000VA/1800W |
Technical Specification | ||||||||
UPS Topology | Line-Interactive | |||||||
Protection Functions | Overload; Short-Circuit; Over Temp.; Utility Voltage High/low; BAT Voltage High/low(Shutdown Protection) | |||||||
Overload | > 110% Alarm Shutdown | |||||||
Surge/Short-Circuit Protection | Input Fuses Protection(AC Mode),Circuit Auto Protection(BAT Mode) | |||||||
Display | LCD | |||||||
Alarm | Utility Power Fault, BAT Low, Overload, UPS Fault | |||||||
Mute | Auto | |||||||
Temperature | 0 ~ 40℃ | |||||||
Humidity | < 95% Non-Condensing | |||||||
Input Specification | ||||||||
Input Voltage Range | 140-290Vac | 170-280Vac | ||||||
Input Frequency Range | 50Hz±10% | |||||||
Output Specification | ||||||||
AVR | Intelligent Auto AVR Function | |||||||
Output Voltage(AC mode) | 220Vac±10% | |||||||
Output Voltage(BAT Mode) | 220Vac±10% | |||||||
Output Freq.(BAT Mode) | 50Hz±10% | |||||||
Output Waveform | Modified Sine wave(BAT Mode) | |||||||
AC-DC Switching Time | 2-6ms | |||||||
BAT Parameters | ||||||||
Type | Sealed Lead-Acid Maintenance Free Battery | |||||||
Rated Voltage/ Units | 12V/4Ah×1P | 12V/7Ah×1P | 12V/9Ah×1P | 12V/7Ah×2P | 12V/7Ah×2P | 12V/9Ah×2P | 12V/9Ah×2P | 12V/9Ah×4P |
Charging Time | 4-6 Hours to 90% | |||||||
Physical Specification | ||||||||
Size in mm(W×H×D) | 101 ×297 ×142 | 140 ×370 ×165 | 138x166x466 | |||||
Net Weight Kg | 3.5 | 4.2 | 4.9 | 8 | 9.6 | 11.1 | 11.5 | 20 |
Note: Specification are subject to change without further notice. |