UPS Solutions
On-Line High Frequency Series
T-4001 1-In / 1-Out, with built-in battery, (1-10KVA)
T-4001 1-In / 1-Out, without battery, (1-10KVA)
T-4002 3-In / 1-Out, without battery, (10-20KVA)
T-4003 3-In / 3-Out, without battery, (10-120KVA)
T-4003 3-In / 3-Out, compatible with built-in battery, (10-40KVA)
T-4003 3-In / 3-Out, Eco Series, with battery, (10-20KVA)
T-4003 3-In / 3-Out, Eco Series, without battery, (10-40KVA)
On-Line Low Frequency Series
T-4101 1-In / 1-Out, built-in battery, (1-6KVA)
T-4101 1-In / 1-Out, without battery, (1-15KVA)
T-4102 3-In / 1-Out, without battery (6-30KVA)
T-4103 3-In / 3-Out, without battery, (10-120KVA)
T-4103 3-In / 3-Out, without battery, (160-600KVA)
Rack-Mountable Series
T-4111 1-In / 1-Out, Low frequency, without battery, (1-10KVA)
T-4011 1-In / 1-Out, High frequency, built-in battery, (1-10KVA)
T-4011 1-In / 1-Out, High frequency, without battery, (1-10KVA)
T-4012 3-In / 1-Out, High frequency, without battery, (10-20KVA)
Modular Series
T-6003 3-In / 3-Out, High frequency, without battery, (30-300KVA)
T-6003 3-In / 3-Out, High frequency, without battery, (50-600KVA), 1 PF (50-600KVA)
Custom Design Online UPS
1 Phase In - 1 Phase Out
T-4101A (3-10kVA)
T-8001 (1- 3kVA)
T-8002(1- 10kVA)
Line Interactive UPS
T-3101 1-In/1-Out, Pure sine wave, built-in battery, (1-3KVA)
T-3101 1-In/1-Out, Pure Sine wave, without battery, (1-10KVA)
T-3001 1-In/1-Out, Modified Sine wave, built-in battery, (400-3000VA)
Online Inverter Series
Power Inverter Series
Automatic Voltage Regulators/Line Conditioners
AVR-1000 (Servo Control)
Single Phase (10-100kVA)
Three Phase (10-3000kVA)
AVR-1001 (Static Control)
Single Phase (1-50kVA)
Three Phase (10-2000kVA)
AVR-1002 (Relay Control)
Single Phase (1-20kVA)
Optional UPS Components
SNMP Adaptor/Card
Static Transfer Switches
Single Phase 3-32A
Three Phase 100-400A
i-power Remote Management System (RMS)
Battery Solutions
AGM Valve Regulated Sealed Lead Acid 12Volt
E-GFM Series Range: 5Ah – 200Ah
Gel Valve Regulated Sealed Lead Acid 12Volt
E-GH Series Range: 26Ah – 200Ah
Pure Gel (Deep Cycle) Valve Regulated Sealed Lead Acid 12Volt
E-GD Series Range: 26Ah – 200Ah
AGM (Deep Cycle) Valve Regulated Sealed Lead Acid 12Volt
E-AD Series Range: 26Ah – 200Ah
Battery Cabinets and Racks
7Ah-200Ah

T-4002 3-In / 1-Out, without battery, 0.8 & 0.9 PF (10-20KVA)

The i-power T-4001 series is a true online double-conversion UPS that can provide your critical equipment with reliable and stable sine wave power. It features significant advantages, including an output power factor up to 0.9 and up to 90% AC-AC efficiency for greater energy savings.

It is a versatile, high quality, and cost-competitive UPS developed to handle a wide voltage range and inconsistent power conditions. The T-4002 series provides a safe power supply guaranteed for mission-critical applications such as computer equipment, telecommunication devices, precision instrument, network termination equipment, and more.

Product Highlights:

  • Wide Input Voltage Range Allows the UPS to work in harsh environments and reduces battery discharging time.
  • IGBT technology to achieve high overall efficiency up to 90%.
  • High input power factor (0.99) and low harmonic distortion (THDI 5%) saves upstream investment.
  • Can be connected with all kinds of generators to save customers costs.
  • True online double-conversion topology and zero transfer time to battery provides 24/7

full-time protection.

ModelOH2010T81600SOH2015T81600SOH2020T81600S
Capacity10KVA/8KW15KVA/12KW20KVA/16KW
ModelOH2010T92000SOH2015T92000SOH2020T92000S
Capacity10KVA/9KW15KVA/13.5KW20KVA/18KW
Host Machine Specification
UPS StructureOnline Double Conversion - Tower Type
TopologyHigh Frequency, Transformer Less
Overall Efficiency (AC-AC )> 90%
Noise(In 2 meters)< 50dB
Working Temp0-40℃
Storage Temp-15 ~ 60℃(Without BATs)
Humidity< 95% Non Condensing
Safety StandardGB/T14715; EN62040-1
EMC StandardEN 50091-1/2, EN62040-2
ProtectionsOverload, Short-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low
Generator CompatibilityAvailable
DC StartAvailable
Manual Maintenance BypassOptional
DisplayLCD/LED: UPS Status, INV Status, Bypass Status, BAT Status, BAT %, Load %, Fault Messages
AlarmAuto
MuteAuto
Rectifier Specification
Input Voltage Range304 ~ 478Vac
Input Frequency Range45-65Hz(Auto Tracking)
Input PF0.99
THDI< 5%
Output Specification
Output Voltage220Vac
Output PF0.8/0.9
Output Voltage Regulation220Vac±1%(Static Load);220Vac±2%(50-0% Sudden Change);220Vac±3%(100-0% Sudden Change)
Output Freq. (BAT Mode)50Hz± 0.2%
Output WaveformPure Sine wave
Distortion< 1%(Linear Full Load),< 3%(100% Non-Linear Load)
Overload> 120%: More than 1 min
> 150%: 300ms transfer to bypass
Crest Ratio3∶1
Efficiency> 90%
Short-CircuitCircuit Auto Protection, Output Voltage/Current
Output AbnormalINV Output Auto-Locked Protection
Noise SuppressionEMI/RFI Wave filter
BAT LowShutdown Protection
Dynamic Response3% at full load,recovering in 20ms
Auto-RestartAvailable
Software ControlAvailable
Bypass Specification
Static Bypass Transfer Time0ms
Static Bypass Range80Vac± 5%~285Vac±5%
Bypass - INV Transfer Time2ms
Battery Specification
TypeSealed Lead Acid Maintenance Free
VDC192/240 Vdc192/240 Vdc192/ 240 Vdc
Charging Current5Amp5Amp5Amp
Communication Specification
Standard Communication PortRs232
OptionalSNMP/RS485/ Dry Contact
Remote SoftwareMulti-functional Monitoring System, Online and BAT Mode Status, BAT Fault, Remote Control
Physical Parameters
Dimensions in mm (D×W×H)500×248×620
Net Weight (Kg)273535
Note:Specification are subject to change without further notice.