UPS Solutions
On-Line High Frequency Series
T-4001 1-In / 1-Out, with built-in battery, (1-10KVA)
T-4001 1-In / 1-Out, without battery, (1-10KVA)
T-4002 3-In / 1-Out, without battery, (10-20KVA)
T-4003 3-In / 3-Out, without battery, (10-120KVA)
T-4003 3-In / 3-Out, compatible with built-in battery, (10-40KVA)
T-4003 3-In / 3-Out, Eco Series, with battery, (10-20KVA)
T-4003 3-In / 3-Out, Eco Series, without battery, (10-40KVA)
On-Line Low Frequency Series
T-4101 1-In / 1-Out, built-in battery, (1-6KVA)
T-4101 1-In / 1-Out, without battery, (1-15KVA)
T-4102 3-In / 1-Out, without battery (6-30KVA)
T-4103 3-In / 3-Out, without battery, (10-120KVA)
T-4103 3-In / 3-Out, without battery, (160-600KVA)
Rack-Mountable Series
T-4111 1-In / 1-Out, Low frequency, without battery, (1-10KVA)
T-4011 1-In / 1-Out, High frequency, built-in battery, (1-10KVA)
T-4011 1-In / 1-Out, High frequency, without battery, (1-10KVA)
T-4012 3-In / 1-Out, High frequency, without battery, (10-20KVA)
Modular Series
T-6003 3-In / 3-Out, High frequency, without battery, (30-300KVA)
T-6003 3-In / 3-Out, High frequency, without battery, (50-600KVA), 1 PF (50-600KVA)
Custom Design Online UPS
1 Phase In - 1 Phase Out
T-4101A (3-10kVA)
T-8001 (1- 3kVA)
T-8002(1- 10kVA)
Line Interactive UPS
T-3101 1-In/1-Out, Pure sine wave, built-in battery, (1-3KVA)
T-3101 1-In/1-Out, Pure Sine wave, without battery, (1-10KVA)
T-3001 1-In/1-Out, Modified Sine wave, built-in battery, (400-3000VA)
Online Inverter Series
Power Inverter Series
Automatic Voltage Regulators/Line Conditioners
AVR-1000 (Servo Control)
Single Phase (10-100kVA)
Three Phase (10-3000kVA)
AVR-1001 (Static Control)
Single Phase (1-50kVA)
Three Phase (10-2000kVA)
AVR-1002 (Relay Control)
Single Phase (1-20kVA)
Optional UPS Components
SNMP Adaptor/Card
Static Transfer Switches
Single Phase 3-32A
Three Phase 100-400A
i-power Remote Management System (RMS)
Battery Solutions
AGM Valve Regulated Sealed Lead Acid 12Volt
E-GFM Series Range: 5Ah – 200Ah
Gel Valve Regulated Sealed Lead Acid 12Volt
E-GH Series Range: 26Ah – 200Ah
Pure Gel (Deep Cycle) Valve Regulated Sealed Lead Acid 12Volt
E-GD Series Range: 26Ah – 200Ah
AGM (Deep Cycle) Valve Regulated Sealed Lead Acid 12Volt
E-AD Series Range: 26Ah – 200Ah
Battery Cabinets and Racks
7Ah-200Ah

T-4101 1-In / 1-Out, built-in battery, 0.8 PF (1-6KVA)

T-4101 1-In / 1-Out, built-in battery, 0.8 PF (1-6KVA)

The i-power T-4101 series is a true online double-conversion UPS that can provide your critical equipment with reliable and stable sine wave power. It features significant advantages, including an output power factor of 0.8 and up to 98% AC-AC efficiency for greater energy savings.

 

It is a versatile, high quality, and cost-competitive UPS developed to handle a wide voltage range and inconsistent power conditions. The T-4101 series provides a safe power supply guaranteed for mission-critical applications such as computer equipment, telecommunication devices, precision instrument, network termination equipment, and more.

 

Product Highlights:

  • Wide Input Voltage Range; Single Phase 160Vac to 280Vac.
  • High Efficiency 98% under ECO Mode.
  • Battery low/over charged sensor to protect the charger.
  • Advanced SCR rectifier and IGBT inverter technology.
  • Surge current protection technology to manage sudden impact of 0% to 100% load immediately without transfer to bypass.
  • Front to rear ventilation design to reduce the MTTR rate of the UPS.
ModelOL1001T80607SOL1002T80607SOL1003T80807SOL1006T81607S
Capacity1KVA/0.8KW2KVA/1.6KW3KVA/2.4KW6KVA/4.8KW
Technical Specification
UPS StructureOnline Double Conversion
TopologyLow Frequency with Output Isolation Transformer
Overall Efficiency (AC-AC )> 85%
Noise(In 2 meters)< 50dB
Working Temp-10-40℃
Storage Temp-25 ~ 60℃(Without Batteries)
Humidity< 95%Non-Condensing
Safety StandardIEC62040
Parallel RedundancyAvailable
ProtectionsOverload, Short-Circuit, Over Temp., Utility Power Voltage High/low, BAT Voltage High/low
DC StartAvailable
Generator CompatibilityAvailable
DisplayLCD Display
MuteAuto
IP RatingIP20
Cooling SystemIntelligent Speed Control Cooling Fan
Elevation<1000M,Without Derating
Rectifier Specification
Input Voltage220/200/230/240Vac Single Phase
Input Voltage Range160-280Vac
Input Frequency Range50Hz±5%
Soft-Start> 20 Seconds
Output Specification
Output Voltage220/200/230/240Vac
Output PF0.8
Output Voltage Regulation220Vac±1%( Static Load ),220Vac±2%(50~0% Sudden Change)
Output Freq50Hz±0.1%(BAT Mode)
Distortion<1%(Linear Full Load),< 3%(Non-Linear Full Load)
Frequency Tracking Range46-54Hz
Output WaveformPure Sine Wave
Overload> 125%: More than 1 Min;
> 150%: More than 300ms
Noise SuppressionEMI/RFI Wave Filter
Crest Ratio3∶1
Short-CircuitCircuit Auto Protection Output Voltage/Current
Output AbnormalINV. Output Auto-Locked Protection
Bypass Specification
Static Bypass Transfer Time0ms
Static Bypass Range220Vac(-15~+15%)
Frequency Range±1Hz, ±2Hz,±3Hz Adjustable
Bypass - INV Transfer Time2ms
Frequency Tracking Speed0.5-2hz/s
Alarm Specification
AlarmUtility Power Fault, BAT Voltage Low, Overload,UPS Fault
MuteAuto
Battery Specification
TypeSealed Lead Acid Maintenance Free
VDC - AH Rating72Vdc - 7Ah72Vdc - 7Ah96Vdc - 7Ah192Vdc - 7Ah
Charging Current1A1A1A1A
BAT LowShutdown Protection
Communication Specification
Standard Communication PortRs232
OptionalSNMP/RS485/ Dry Contact
Remote SoftwareMulti-functional Monitoring System, Online and BAT Mode Status, BAT Fault, Remote Control
Physical Parameters
Dimensions(W×D×H) mm220×510×395220×610×635
Net Weight (Kg)37.538.54984
Note:Specification are subject to change without further notice.